Focus. PRO 6. 00. Programmable Thermostat (TH6. D)? The location of the model number varies depending upon the thermostat. If the thermostat is battery operated and the batteries are accessed from the front of the thermostat, please check the area around the batteries. If the batteries are on the back of the thermostat or if the thermostat is not battery operated, the model number should be on the back of the thermostat once the thermostat is removed from its base. If your thermostat has a mechanical clock, the model number is on a sticker on the horizontal surface above the clock. The Auto position will allow the system fan to operate whenever the heating or cooling system is turned on by the thermostat. The On position will turn the fan on to run continuously, regardless whether heating or cooling system is turned on by the thermostat or not. The Circ (Circulate) position if available will run the fan approximately 3. The most common type of voltage from a central heating and/or cooling system is 2. Vac). The old thermostat may say somewhere on the thermostat that it is for 2. Vac) or maximum 3. Vac). If you see 1. Vac or 2. 40 Vac on the thermostat, a low voltage thermostat will NOT work with your system. You will need a line voltage thermostat. This type of voltage is common with electric baseboard heating. Regardless of the voltage, Honeywell strongly suggests that you turn off the power to the system at the furnace, at the fuse, or at the circuit breaker panel before installing or replacing a thermostat. If you are unsure about your voltage, please contact a local heating and cooling contractor in your area for assistance. Information about recycling thermostats containing mercury can be found at: thermostat- recycle. Stage two of heat or cool turns on right away when I move the temperature higher or lower. It will run the second or third stage only as long as necessary to reach new temperature setting. If your thermostat does not show auto, you may not have this feature. This will allow the freon to reverse and heat the home or cool the home. Honeywell uses an O terminal to energize the valve in cooling and a B terminal to energize the valve in heating. Though the program keeps. Teaches Typing guide your typing. The Focus Pro 5000 non-programmable thermostat is easy to set up and use. FocusPRO Honeywell Thermostats. Selection Guide 15 products shown. FocusPRO 5000/6000 and PRO 3000/4000. Some manufacturers of heat pumps may use the B terminal to energize in heating, while a vast majority energize the O terminal in cooling. How often your heat turns on and off depends on several factors including the type of heating system you have and load conditions (in other words, how hot or cold it is outside). How to Program Honeywell 5000 Pro Thermostat. Guide to thermostats and settings. How to Program a Honeywell Programmable Thermostat. Honeywell focus pro 5000 installation manual is available in our digital library an online access to it. Why Choose Honeywell; Undergraduate & Graduate Opportunities; CONTACT US; Canada. Find great deals on eBay for honeywell 5000 thermostat honeywell 8000 thermostat. How to Program a Honeywell. Honeywell Thermostat; Honeywell Pro 5000. A typical mid- efficiency forced air system will cycle about five times in an hour (5. CPH) under typical load conditions. A typical high efficiency furnace or hot water system would cycle less than that. The installer can adjust the cycle rate setting on the thermostat. Buy Honeywell TH5220D1003 FocusPro 5000 Universal Non. 5000 Universal Non-Programmable Thermostat - Two Stage. 5000 Universal Non-Programmable Thermostat.This means the thermostat takes into account not just the ambient air temperature but also the radiant temperature of objects in the room (i. Room thermometers often only read ambient air temperature so they will not match the thermostat reading. Also, Honeywell thermostats do round in the display to the nearest whole number (half number in Celsius) and to the temperature setting. For example, if you have the thermostat set to 7. The actual temperature did fall to 7. Often the heat pump also has some sort of backup or auxiliary heat for when it is cold outside. Get Instant Access To Honeywell Thermostat Focus Pro 5000 PDF Ebook HONEYWELL THERMOSTAT. The backup or auxiliary heat could be electric heat strips or a fossil fuel furnace. Thermostats that control heat pumps with backup or auxiliary heat typically have an Em Heat (Emergency heat) position. When the system switch is moved to the Em Ht. The compressor is disabled. If replacing a thermostat on a heat pump system, verify your thermostat is compatible. The noise you are hearing is likely from another electronic device which is near the thermostat. Check for a smoke detector, door bell, or security system. First check that the thermostat is set to the Cool position. Make sure the temperature is set lower than the Inside temperature reading. Also check the circuit breaker and reset if necessary. Make sure that the furnace door is closed securely. If “wait” is in the screen or “cool on” is flashing – wait 5 minutes for the system to safely respond. The thermostat will indicate it is asking for the cooling to turn on when . If this message is in the display, the thermostat is asking for the heat to be on and there is a likely a problem outside of the thermostat preventing the cooling from running. First check that the thermostat is set to the Heat position. Make sure the temperature is set higher than the Inside temperature reading. Also check the circuit breaker and reset if necessary. Make sure that the furnace door is closed securely. If “wait” is in the screen or “heat on” is flashing – wait 5 minutes for the system to safely respond. The thermostat will indicate it is asking for the heat to turn on when . If this message is in the display, the thermostat is asking for the heat to be on and there is a likely a problem outside of the thermostat preventing the heat from running. This allows the thermostat to . So the temperature is reached at the time you set. For example: Set the Wake time to 6am, and the temperature to 7. F. The heat will come on before 6am, so the temperature is 7. F by the time you wake at 6am. If “wait” is in the screen or “cool on” is flashing – wait 5 minutes for the system to safely respond.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
January 2017
Categories |